Anritsu Site Master S332C

S331cCovering the 25 MHz to 4000 MHz frequency band, the Site Master S331C and S332C site management tools are designed to accurately locate and identify RF cable feed-line and antenna system faults. These models are ideally suited for any experience level user in commissioning and maintenance of today's wire less systems infrastructures including VHF, broadcasting, paging, cellular, PCS/GSM, ISM, and WLL applications. Both S331C and S332C replace all S300 and S400 Series Site Master models.

The S332C features spectrum analysis capability in addition to return loss/SWR, cable loss and distance-to-fault measurements, allowing field engineers and technicians the ability to easily identify and solve RF system problems such as coverage, interference, and other path related signal problems. S332C spectrum analysis ranges from 100 kHz to 3 G Hz.

The S331C/S332C models include data analysis software, soft carrying case, rechargeable/field-replaceable battery, AC/DC power supply, 12.5V automobile cigarette lighter adapter and users guide.

Specifications

  • Frequency range 25 to 4,000 MHz
  • Measures return loss, SWR, cable loss, and distance to fault
  • Integral synthesized signal generator
  • Return loss range 0.00
  • Distance to fault range 1000 m.
  • Insertion loss range -120.00 to +100 dB
  • Cable loss range (one port) 0.00 to 20.00 dB
  • Type n(f) port.
  • RS232 interface for printer or PC
  • Analysis software discs included containing distance to fault and Smith chart tools
  • Lightweight at only 1.36kg - 2.14kg
  • Alphanumeric Labeling of Saved Measurements
  • Automatic Time and Date Stamp of Saved Data
  • Rechargeable, Field Replaceable Battery
  • RS232 Interface